{"id":1626,"date":"2025-05-07T22:31:39","date_gmt":"2025-05-07T22:31:39","guid":{"rendered":"https:\/\/shopstemaengineering.com\/?post_type=product&#038;p=1626"},"modified":"2026-02-10T04:54:43","modified_gmt":"2026-02-10T04:54:43","slug":"eaton-pad-mounted-transformers-up-to-34-5-kv-75-10000-kva","status":"publish","type":"product","link":"https:\/\/shopstemaengineering.com\/fr\/produit\/eaton-pad-mounted-transformers-up-to-34-5-kv-75-10000-kva\/","title":{"rendered":"Eaton Pad-Mounted Transformers (Up to 34.5 kV | 75 \u2013 10,000+ kVA)"},"content":{"rendered":"<h3 class=\"\" data-start=\"318\" data-end=\"401\">Secure, Weatherproof Power Distribution for Commercial &amp; Utility Applications<\/h3>\n<p class=\"\" data-start=\"402\" data-end=\"505\">\ud83d\udcde <strong data-start=\"405\" data-end=\"418\">Call Now:<\/strong> +254 707 122 122 | \ud83c\udf10 <strong data-start=\"441\" data-end=\"505\"><a class=\"\" href=\"https:\/\/shopstemaengineering.com\/fr\/\" target=\"_new\" rel=\"noopener\" data-start=\"443\" data-end=\"503\">shopstemaengineering.com<\/a><\/strong><\/p>\n<hr class=\"\" data-start=\"507\" data-end=\"510\" \/>\n<p class=\"\" data-start=\"1022\" data-end=\"1218\">\n<hr class=\"\" data-start=\"1220\" data-end=\"1223\" \/>\n<h2 class=\"\" data-start=\"1225\" data-end=\"1255\">\u2699\ufe0f Technical Specifications<\/h2>\n<div class=\"_tableContainer_16hzy_1\">\n<div class=\"_tableWrapper_16hzy_14 group flex w-fit flex-col-reverse\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"1257\" data-end=\"2382\">\n<thead data-start=\"1257\" data-end=\"1349\">\n<tr data-start=\"1257\" data-end=\"1349\">\n<th data-start=\"1257\" data-end=\"1286\" data-col-size=\"sm\"><strong data-start=\"1259\" data-end=\"1276\">Specification<\/strong><\/th>\n<th data-start=\"1286\" data-end=\"1349\" data-col-size=\"md\"><strong data-start=\"1288\" data-end=\"1299\">Details<\/strong><\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"1444\" data-end=\"2382\">\n<tr data-start=\"1444\" data-end=\"1537\">\n<td data-start=\"1444\" data-end=\"1473\" data-col-size=\"sm\"><strong data-start=\"1446\" data-end=\"1462\">Power Rating<\/strong><\/td>\n<td data-col-size=\"md\" data-start=\"1473\" data-end=\"1537\">75 kVA \u2013 10,000+ kVA<\/td>\n<\/tr>\n<tr data-start=\"1538\" data-end=\"1631\">\n<td data-start=\"1538\" data-end=\"1567\" data-col-size=\"sm\"><strong data-start=\"1540\" data-end=\"1559\">Primary Voltage<\/strong><\/td>\n<td data-col-size=\"md\" data-start=\"1567\" data-end=\"1631\">Up to 34.5 kV<\/td>\n<\/tr>\n<tr data-start=\"1632\" data-end=\"1725\">\n<td data-start=\"1632\" data-end=\"1661\" data-col-size=\"sm\"><strong data-start=\"1634\" data-end=\"1655\">Secondary Voltage<\/strong><\/td>\n<td data-col-size=\"md\" data-start=\"1661\" data-end=\"1725\">208 V \u2013 15 kV<\/td>\n<\/tr>\n<tr data-start=\"1726\" data-end=\"1819\">\n<td data-start=\"1726\" data-end=\"1755\" data-col-size=\"sm\"><strong data-start=\"1728\" data-end=\"1745\">Configuration<\/strong><\/td>\n<td data-col-size=\"md\" data-start=\"1755\" data-end=\"1819\">Live-front or Dead-front<\/td>\n<\/tr>\n<tr data-start=\"1820\" data-end=\"1913\">\n<td data-start=\"1820\" data-end=\"1849\" data-col-size=\"sm\"><strong data-start=\"1822\" data-end=\"1832\">Phases<\/strong><\/td>\n<td data-col-size=\"md\" data-start=\"1849\" data-end=\"1913\">Three-phase (single-phase options available)<\/td>\n<\/tr>\n<tr data-start=\"1914\" data-end=\"2007\">\n<td data-start=\"1914\" data-end=\"1943\" data-col-size=\"sm\"><strong data-start=\"1916\" data-end=\"1932\">Cooling Type<\/strong><\/td>\n<td data-col-size=\"md\" data-start=\"1943\" data-end=\"2007\">KNAN (Natural Air), KNAF (Air Forced)<\/td>\n<\/tr>\n<tr data-start=\"2008\" data-end=\"2101\">\n<td data-start=\"2008\" data-end=\"2037\" data-col-size=\"sm\"><strong data-start=\"2010\" data-end=\"2027\">Fluid Options<\/strong><\/td>\n<td data-col-size=\"md\" data-start=\"2037\" data-end=\"2101\">Mineral oil, Envirotemp\u2122 FR3 (biodegradable), Silicone<\/td>\n<\/tr>\n<tr data-start=\"2102\" data-end=\"2194\">\n<td data-start=\"2102\" data-end=\"2134\" data-col-size=\"sm\"><strong data-start=\"2104\" data-end=\"2133\">BIL (Basic Impulse Level)<\/strong><\/td>\n<td data-col-size=\"md\" data-start=\"2134\" data-end=\"2194\">Up to 150 kV (depending on rating)<\/td>\n<\/tr>\n<tr data-start=\"2195\" data-end=\"2288\">\n<td data-start=\"2195\" data-end=\"2224\" data-col-size=\"sm\"><strong data-start=\"2197\" data-end=\"2210\">Enclosure<\/strong><\/td>\n<td data-col-size=\"md\" data-start=\"2224\" data-end=\"2288\">Tamper-proof, weather-resistant steel or stainless steel<\/td>\n<\/tr>\n<tr data-start=\"2289\" data-end=\"2382\">\n<td data-start=\"2289\" data-end=\"2318\" data-col-size=\"sm\"><strong data-start=\"2291\" data-end=\"2304\">Standards<\/strong><\/td>\n<td data-col-size=\"md\" data-start=\"2318\" data-end=\"2382\">IEEE C57.12.00, ANSI, DOE 2016, NEMA, UL listed<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"sticky end-(--thread-content-margin) h-0 self-end select-none\">\n<div class=\"absolute end-0 flex items-end\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<hr class=\"\" data-start=\"2384\" data-end=\"2387\" \/>\n<h2 class=\"\" data-start=\"2389\" data-end=\"2418\">\ud83c\udfc6 Key Features &amp; Benefits<\/h2>\n<h3 class=\"\" data-start=\"2420\" data-end=\"2471\">\ud83d\udee1\ufe0f Tamper-Resistant &amp; Safe for Public Access<\/h3>\n<ul data-start=\"2472\" data-end=\"2603\">\n<li class=\"\" data-start=\"2472\" data-end=\"2535\">\n<p class=\"\" data-start=\"2474\" data-end=\"2535\">Lockable, weatherproof cabinets prevent unauthorized access<\/p>\n<\/li>\n<li class=\"\" data-start=\"2536\" data-end=\"2603\">\n<p class=\"\" data-start=\"2538\" data-end=\"2603\">Ideal for use in schools, malls, residential areas, and sidewalks<\/p>\n<\/li>\n<\/ul>\n<h3 class=\"\" data-start=\"2605\" data-end=\"2648\">\u26a1 Reliable Outdoor Power Distribution<\/h3>\n<ul data-start=\"2649\" data-end=\"2765\">\n<li class=\"\" data-start=\"2649\" data-end=\"2709\">\n<p class=\"\" data-start=\"2651\" data-end=\"2709\">Withstands environmental extremes (rain, wind, UV, dust)<\/p>\n<\/li>\n<li class=\"\" data-start=\"2710\" data-end=\"2765\">\n<p class=\"\" data-start=\"2712\" data-end=\"2765\">Designed for continuous duty with minimal maintenance<\/p>\n<\/li>\n<\/ul>\n<h3 class=\"\" data-start=\"2767\" data-end=\"2811\">\ud83c\udf0d Environmentally Responsible Options<\/h3>\n<ul data-start=\"2812\" data-end=\"2943\">\n<li class=\"\" data-start=\"2812\" data-end=\"2883\">\n<p class=\"\" data-start=\"2814\" data-end=\"2883\">Available with <strong data-start=\"2829\" data-end=\"2848\">Envirotemp\u2122 FR3<\/strong> fluid (biodegradable, fire-safe)<\/p>\n<\/li>\n<li class=\"\" data-start=\"2884\" data-end=\"2943\">\n<p class=\"\" data-start=\"2886\" data-end=\"2943\">Meets modern environmental and energy-efficiency mandates<\/p>\n<\/li>\n<\/ul>\n<h3 class=\"\" data-start=\"2945\" data-end=\"2995\">\ud83d\udd27 Flexible Installation &amp; Compact Footprint<\/h3>\n<ul data-start=\"2996\" data-end=\"3129\">\n<li class=\"\" data-start=\"2996\" data-end=\"3067\">\n<p class=\"\" data-start=\"2998\" data-end=\"3067\">Can be placed on a concrete pad in urban areas or utility corridors<\/p>\n<\/li>\n<li class=\"\" data-start=\"3068\" data-end=\"3129\">\n<p class=\"\" data-start=\"3070\" data-end=\"3129\">Reduced site prep and trenching vs. substation-style setups<\/p>\n<\/li>\n<\/ul>\n<h3 class=\"\" data-start=\"3131\" data-end=\"3167\">\ud83e\udde9 Wide Range of Customization<\/h3>\n<ul data-start=\"3168\" data-end=\"3298\">\n<li class=\"\" data-start=\"3168\" data-end=\"3236\">\n<p class=\"\" data-start=\"3170\" data-end=\"3236\">Tap changers, load-break switches, loop feeds, fuse compartments<\/p>\n<\/li>\n<li class=\"\" data-start=\"3237\" data-end=\"3298\">\n<p class=\"\" data-start=\"3239\" data-end=\"3298\">SCADA, arc-flash protection, remote monitoring integrations<\/p>\n<\/li>\n<\/ul>\n<hr class=\"\" data-start=\"3300\" data-end=\"3303\" \/>\n<h2 class=\"\" data-start=\"3305\" data-end=\"3332\">\ud83d\udd04 Common Configurations<\/h2>\n<div class=\"_tableContainer_16hzy_1\">\n<div class=\"_tableWrapper_16hzy_14 group flex w-fit flex-col-reverse\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"3334\" data-end=\"4131\">\n<thead data-start=\"3334\" data-end=\"3465\">\n<tr data-start=\"3334\" data-end=\"3465\">\n<th data-start=\"3334\" data-end=\"3359\" data-col-size=\"sm\"><strong data-start=\"3336\" data-end=\"3350\">Model Type<\/strong><\/th>\n<th data-start=\"3359\" data-end=\"3381\" data-col-size=\"sm\"><strong data-start=\"3361\" data-end=\"3380\">Primary Voltage<\/strong><\/th>\n<th data-start=\"3381\" data-end=\"3405\" data-col-size=\"sm\"><strong data-start=\"3383\" data-end=\"3404\">Secondary Voltage<\/strong><\/th>\n<th data-start=\"3405\" data-end=\"3425\" data-col-size=\"sm\"><strong data-start=\"3407\" data-end=\"3424\">Configuration<\/strong><\/th>\n<th data-start=\"3425\" data-end=\"3465\" data-col-size=\"sm\"><strong data-start=\"3427\" data-end=\"3439\">Use Case<\/strong><\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"3599\" data-end=\"4131\">\n<tr data-start=\"3599\" data-end=\"3731\">\n<td data-start=\"3599\" data-end=\"3624\" data-col-size=\"sm\">Pad-Mount 500 kVA<\/td>\n<td data-col-size=\"sm\" data-start=\"3624\" data-end=\"3646\">13.8 kV<\/td>\n<td data-col-size=\"sm\" data-start=\"3646\" data-end=\"3671\">480 V<\/td>\n<td data-col-size=\"sm\" data-start=\"3671\" data-end=\"3691\">Dead-front<\/td>\n<td data-col-size=\"sm\" data-start=\"3691\" data-end=\"3731\">Commercial complexes, hospitals<\/td>\n<\/tr>\n<tr data-start=\"3732\" data-end=\"3864\">\n<td data-start=\"3732\" data-end=\"3757\" data-col-size=\"sm\">Pad-Mount 1000 kVA<\/td>\n<td data-col-size=\"sm\" data-start=\"3757\" data-end=\"3779\">33 kV<\/td>\n<td data-col-size=\"sm\" data-start=\"3779\" data-end=\"3804\">415\/240 V<\/td>\n<td data-col-size=\"sm\" data-start=\"3804\" data-end=\"3824\">Live-front<\/td>\n<td data-col-size=\"sm\" data-start=\"3824\" data-end=\"3864\">Utility feeders<\/td>\n<\/tr>\n<tr data-start=\"3865\" data-end=\"3997\">\n<td data-start=\"3865\" data-end=\"3890\" data-col-size=\"sm\">Pad-Mount 2500 kVA<\/td>\n<td data-col-size=\"sm\" data-start=\"3890\" data-end=\"3912\">34.5 kV<\/td>\n<td data-col-size=\"sm\" data-start=\"3912\" data-end=\"3937\">11 kV<\/td>\n<td data-col-size=\"sm\" data-start=\"3937\" data-end=\"3957\">Dead-front<\/td>\n<td data-col-size=\"sm\" data-start=\"3957\" data-end=\"3997\">Industrial parks, airports<\/td>\n<\/tr>\n<tr data-start=\"3998\" data-end=\"4131\">\n<td data-start=\"3998\" data-end=\"4023\" data-col-size=\"sm\">Pad-Mount 7500 kVA<\/td>\n<td data-col-size=\"sm\" data-start=\"4023\" data-end=\"4045\">11 kV<\/td>\n<td data-col-size=\"sm\" data-start=\"4045\" data-end=\"4070\">6.6 kV<\/td>\n<td data-col-size=\"sm\" data-start=\"4070\" data-end=\"4090\">Live-front<\/td>\n<td data-col-size=\"sm\" data-start=\"4090\" data-end=\"4131\">Power-intensive processing plants<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"sticky end-(--thread-content-margin) h-0 self-end select-none\">\n<div class=\"absolute end-0 flex items-end\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<hr class=\"\" data-start=\"4133\" data-end=\"4136\" \/>\n<h2 class=\"\" data-start=\"4138\" data-end=\"4188\">\ud83c\udd9a Eaton vs Competitor Pad-Mounted Transformers<\/h2>\n<div class=\"_tableContainer_16hzy_1\">\n<div class=\"_tableWrapper_16hzy_14 group flex w-fit flex-col-reverse\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"4190\" data-end=\"4939\">\n<thead data-start=\"4190\" data-end=\"4296\">\n<tr data-start=\"4190\" data-end=\"4296\">\n<th data-start=\"4190\" data-end=\"4219\" data-col-size=\"sm\"><strong data-start=\"4192\" data-end=\"4203\">Feature<\/strong><\/th>\n<th data-start=\"4219\" data-end=\"4259\" data-col-size=\"sm\"><strong data-start=\"4221\" data-end=\"4242\">Eaton Pad-Mounted<\/strong><\/th>\n<th data-start=\"4259\" data-end=\"4296\" data-col-size=\"sm\"><strong data-start=\"4261\" data-end=\"4284\">Generic Competitors<\/strong><\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"4405\" data-end=\"4939\">\n<tr data-start=\"4405\" data-end=\"4511\">\n<td data-start=\"4405\" data-end=\"4434\" data-col-size=\"sm\">Tamper-Resistant Design<\/td>\n<td data-col-size=\"sm\" data-start=\"4434\" data-end=\"4474\">\u2705 UL Listed Cabinets<\/td>\n<td data-col-size=\"sm\" data-start=\"4474\" data-end=\"4511\">\ud83d\udd38 May lack UL\/NEMA certification<\/td>\n<\/tr>\n<tr data-start=\"4512\" data-end=\"4618\">\n<td data-start=\"4512\" data-end=\"4541\" data-col-size=\"sm\">Fluid Options<\/td>\n<td data-col-size=\"sm\" data-start=\"4541\" data-end=\"4581\">\u2705 Mineral, Silicone, FR3<\/td>\n<td data-col-size=\"sm\" data-start=\"4581\" data-end=\"4618\">\ud83d\udd38 Often limited to mineral oil<\/td>\n<\/tr>\n<tr data-start=\"4619\" data-end=\"4725\">\n<td data-start=\"4619\" data-end=\"4648\" data-col-size=\"sm\">Dielectric Strength (BIL)<\/td>\n<td data-col-size=\"sm\" data-start=\"4648\" data-end=\"4688\">\u2705 Up to 150 kV<\/td>\n<td data-col-size=\"sm\" data-start=\"4688\" data-end=\"4725\">\ud83d\udd38 Usually up to 95\u2013125 kV<\/td>\n<\/tr>\n<tr data-start=\"4726\" data-end=\"4832\">\n<td data-start=\"4726\" data-end=\"4755\" data-col-size=\"sm\">Safety &amp; Compliance<\/td>\n<td data-col-size=\"sm\" data-start=\"4755\" data-end=\"4795\">\u2705 ANSI, IEEE, NEMA, DOE compliant<\/td>\n<td data-col-size=\"sm\" data-start=\"4795\" data-end=\"4832\">\u26a0\ufe0f Varies widely<\/td>\n<\/tr>\n<tr data-start=\"4833\" data-end=\"4939\">\n<td data-start=\"4833\" data-end=\"4862\" data-col-size=\"sm\">Factory Support<\/td>\n<td data-col-size=\"sm\" data-start=\"4862\" data-end=\"4902\">\u2705 Backed by Eaton engineering<\/td>\n<td data-col-size=\"sm\" data-start=\"4902\" data-end=\"4939\">\ud83d\udd38 Limited OEM support<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"sticky end-(--thread-content-margin) h-0 self-end select-none\">\n<div class=\"absolute end-0 flex items-end\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<hr class=\"\" data-start=\"4941\" data-end=\"4944\" \/>\n<h2 class=\"\" data-start=\"4946\" data-end=\"4970\">\ud83c\udfed Ideal Applications<\/h2>\n<div class=\"_tableContainer_16hzy_1\">\n<div class=\"_tableWrapper_16hzy_14 group flex w-fit flex-col-reverse\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"4972\" data-end=\"5690\">\n<thead data-start=\"4972\" data-end=\"5060\">\n<tr data-start=\"4972\" data-end=\"5060\">\n<th data-start=\"4972\" data-end=\"5002\" data-col-size=\"sm\"><strong data-start=\"4974\" data-end=\"4984\">Sector<\/strong><\/th>\n<th data-start=\"5002\" data-end=\"5060\" data-col-size=\"md\"><strong data-start=\"5004\" data-end=\"5019\">Application<\/strong><\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"5151\" data-end=\"5690\">\n<tr data-start=\"5151\" data-end=\"5240\">\n<td data-start=\"5151\" data-end=\"5181\" data-col-size=\"sm\"><strong data-start=\"5153\" data-end=\"5166\">Utilities<\/strong><\/td>\n<td data-col-size=\"md\" data-start=\"5181\" data-end=\"5240\">Grid edge distribution, pole-to-ground conversion<\/td>\n<\/tr>\n<tr data-start=\"5241\" data-end=\"5330\">\n<td data-start=\"5241\" data-end=\"5271\" data-col-size=\"sm\"><strong data-start=\"5243\" data-end=\"5259\">Data Centers<\/strong><\/td>\n<td data-col-size=\"md\" data-start=\"5271\" data-end=\"5330\">Reliable medium-voltage input for UPS\/panel boards<\/td>\n<\/tr>\n<tr data-start=\"5331\" data-end=\"5420\">\n<td data-start=\"5331\" data-end=\"5361\" data-col-size=\"sm\"><strong data-start=\"5333\" data-end=\"5351\">Shopping Malls<\/strong><\/td>\n<td data-col-size=\"md\" data-start=\"5361\" data-end=\"5420\">Safe transformer mounting in publicly accessible areas<\/td>\n<\/tr>\n<tr data-start=\"5421\" data-end=\"5510\">\n<td data-start=\"5421\" data-end=\"5451\" data-col-size=\"sm\"><strong data-start=\"5423\" data-end=\"5443\">Renewable Energy<\/strong><\/td>\n<td data-col-size=\"md\" data-start=\"5451\" data-end=\"5510\">Grid-tie connections for solar and wind farms<\/td>\n<\/tr>\n<tr data-start=\"5511\" data-end=\"5600\">\n<td data-start=\"5511\" data-end=\"5541\" data-col-size=\"sm\"><strong data-start=\"5513\" data-end=\"5539\">Education &amp; Healthcare<\/strong><\/td>\n<td data-col-size=\"md\" data-start=\"5541\" data-end=\"5600\">Campus-style distribution across multiple buildings<\/td>\n<\/tr>\n<tr data-start=\"5601\" data-end=\"5690\">\n<td data-start=\"5601\" data-end=\"5631\" data-col-size=\"sm\"><strong data-start=\"5603\" data-end=\"5629\">Commercial Real Estate<\/strong><\/td>\n<td data-col-size=\"md\" data-start=\"5631\" data-end=\"5690\">Subdivision or complex-level power distribution<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"sticky end-(--thread-content-margin) h-0 self-end select-none\">\n<div class=\"absolute end-0 flex items-end\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<hr class=\"\" data-start=\"5692\" data-end=\"5695\" \/>\n<h2 class=\"\" data-start=\"5697\" data-end=\"5720\">\ud83d\udcd0 Optional Features<\/h2>\n<ul data-start=\"5722\" data-end=\"5990\">\n<li class=\"\" data-start=\"5722\" data-end=\"5772\">\n<p class=\"\" data-start=\"5724\" data-end=\"5772\">\ud83e\uddf2 <strong data-start=\"5727\" data-end=\"5755\">Loop Feed or Radial Feed<\/strong> configurations<\/p>\n<\/li>\n<li class=\"\" data-start=\"5773\" data-end=\"5804\">\n<p class=\"\" data-start=\"5775\" data-end=\"5804\">\u2699\ufe0f <strong data-start=\"5778\" data-end=\"5802\">Bayonet &amp; ELSP Fuses<\/strong><\/p>\n<\/li>\n<li class=\"\" data-start=\"5805\" data-end=\"5835\">\n<p class=\"\" data-start=\"5807\" data-end=\"5835\">\ud83d\udd0c <strong data-start=\"5810\" data-end=\"5833\">Load-Break Switches<\/strong><\/p>\n<\/li>\n<li class=\"\" data-start=\"5836\" data-end=\"5869\">\n<p class=\"\" data-start=\"5838\" data-end=\"5869\">\ud83c\udf10 <strong data-start=\"5841\" data-end=\"5867\">SCADA-Ready Monitoring<\/strong><\/p>\n<\/li>\n<li class=\"\" data-start=\"5870\" data-end=\"5922\">\n<p class=\"\" data-start=\"5872\" data-end=\"5922\">\ud83e\uddef <strong data-start=\"5875\" data-end=\"5920\">Pressure Relief Devices &amp; Surge Arrestors<\/strong><\/p>\n<\/li>\n<li class=\"\" data-start=\"5923\" data-end=\"5990\">\n<p class=\"\" data-start=\"5925\" data-end=\"5990\">\ud83c\udff7\ufe0f Custom nameplates, RTDs, alarms, or anti-condensation heaters<\/p>\n<\/li>\n<\/ul>\n<hr class=\"\" data-start=\"5992\" data-end=\"5995\" \/>\n<h2 class=\"\" data-start=\"5997\" data-end=\"6039\">\ud83d\udce6 Why Buy from Shop Stema Engineering?<\/h2>\n<ul data-start=\"6041\" data-end=\"6356\">\n<li class=\"\" data-start=\"6041\" data-end=\"6120\">\n<p class=\"\" data-start=\"6043\" data-end=\"6120\">\ud83c\udfd7\ufe0f <strong data-start=\"6047\" data-end=\"6074\">Site-ready transformers<\/strong> shipped with detailed drawings and diagrams<\/p>\n<\/li>\n<li class=\"\" data-start=\"6121\" data-end=\"6180\">\n<p class=\"\" data-start=\"6123\" data-end=\"6180\">\ud83d\udd27 <strong data-start=\"6126\" data-end=\"6178\">Pre-sale support &amp; transformer sizing assistance<\/strong><\/p>\n<\/li>\n<li class=\"\" data-start=\"6181\" data-end=\"6242\">\n<p class=\"\" data-start=\"6183\" data-end=\"6242\">\ud83c\uddf0\ud83c\uddea <strong data-start=\"6188\" data-end=\"6215\">Local presence in Kenya<\/strong> with technicians on call<\/p>\n<\/li>\n<li class=\"\" data-start=\"6243\" data-end=\"6301\">\n<p class=\"\" data-start=\"6245\" data-end=\"6301\">\ud83d\ude9a <strong data-start=\"6248\" data-end=\"6299\">Delivery, installation, and after-sales service<\/strong><\/p>\n<\/li>\n<li class=\"\" data-start=\"6302\" data-end=\"6356\">\n<p class=\"\" data-start=\"6304\" data-end=\"6356\">\u2705 All units <strong data-start=\"6316\" data-end=\"6356\">tested and certified before dispatch<\/strong><\/p>\n<\/li>\n<\/ul>\n<hr class=\"\" data-start=\"6358\" data-end=\"6361\" \/>\n<h2 class=\"\" data-start=\"6363\" data-end=\"6390\">\ud83d\udcdd Sample Quote Snapshot<\/h2>\n<div class=\"_tableContainer_16hzy_1\">\n<div class=\"_tableWrapper_16hzy_14 group flex w-fit flex-col-reverse\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"6392\" data-end=\"6968\">\n<thead data-start=\"6392\" data-end=\"6462\">\n<tr data-start=\"6392\" data-end=\"6462\">\n<th data-start=\"6392\" data-end=\"6416\" data-col-size=\"sm\"><strong data-start=\"6394\" data-end=\"6407\">Component<\/strong><\/th>\n<th data-start=\"6416\" data-end=\"6462\" data-col-size=\"sm\"><strong data-start=\"6418\" data-end=\"6429\">Details<\/strong><\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"6536\" data-end=\"6968\">\n<tr data-start=\"6536\" data-end=\"6607\">\n<td data-start=\"6536\" data-end=\"6561\" data-col-size=\"sm\">Transformer Rating<\/td>\n<td data-col-size=\"sm\" data-start=\"6561\" data-end=\"6607\">1500 kVA Pad-Mounted Transformer<\/td>\n<\/tr>\n<tr data-start=\"6608\" data-end=\"6680\">\n<td data-start=\"6608\" data-end=\"6633\" data-col-size=\"sm\">Voltage<\/td>\n<td data-col-size=\"sm\" data-start=\"6633\" data-end=\"6680\">11 kV Primary \/ 415 V Secondary<\/td>\n<\/tr>\n<tr data-start=\"6681\" data-end=\"6752\">\n<td data-start=\"6681\" data-end=\"6706\" data-col-size=\"sm\">Fluid Type<\/td>\n<td data-col-size=\"sm\" data-start=\"6706\" data-end=\"6752\">Envirotemp\u2122 FR3<\/td>\n<\/tr>\n<tr data-start=\"6753\" data-end=\"6824\">\n<td data-start=\"6753\" data-end=\"6778\" data-col-size=\"sm\">Accessories<\/td>\n<td data-col-size=\"sm\" data-start=\"6778\" data-end=\"6824\">Load-Break Switch, Fuses, Arrestors<\/td>\n<\/tr>\n<tr data-start=\"6825\" data-end=\"6896\">\n<td data-start=\"6825\" data-end=\"6850\" data-col-size=\"sm\">Enclosure<\/td>\n<td data-col-size=\"sm\" data-start=\"6850\" data-end=\"6896\">NEMA 3R, Dead-Front<\/td>\n<\/tr>\n<tr data-start=\"6897\" data-end=\"6968\">\n<td data-start=\"6897\" data-end=\"6922\" data-col-size=\"sm\">Lead Time<\/td>\n<td data-start=\"6922\" data-end=\"6968\" data-col-size=\"sm\">6\u201310 weeks<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"sticky end-(--thread-content-margin) h-0 self-end select-none\">\n<div class=\"absolute end-0 flex items-end\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<hr class=\"\" data-start=\"6970\" data-end=\"6973\" \/>\n<h2 class=\"\" data-start=\"6975\" data-end=\"7005\">\ud83d\udcde Let\u2019s Power Your Project<\/h2>\n<p class=\"\" data-start=\"7007\" data-end=\"7260\">If you&#8217;re seeking <strong data-start=\"7025\" data-end=\"7073\">a compact, secure, and efficient transformer<\/strong> for outdoor or high-traffic zones, the <strong data-start=\"7113\" data-end=\"7146\">Eaton Pad-Mounted Transformer<\/strong> is your go-to solution. From residential substations to utility networks, Shop Stema Engineering has you covered.<\/p>\n<p class=\"\" data-start=\"7262\" data-end=\"7419\">\ud83d\udcde <strong data-start=\"7265\" data-end=\"7283\">Call\/WhatsApp:<\/strong> +254 707 122 122<br data-start=\"7300\" data-end=\"7303\" \/>\ud83d\udce7 <strong data-start=\"7306\" data-end=\"7316\">Email:<\/strong> <a class=\"cursor-pointer\" rel=\"noopener\" data-start=\"7317\" data-end=\"7342\">info@stemaengineering.com<\/a><\/p>","protected":false},"excerpt":{"rendered":"<h2 class=\"\" data-start=\"512\" data-end=\"534\">\ud83e\udded Product Overview<\/h2>\n<p class=\"\" data-start=\"536\" data-end=\"1020\"><strong data-start=\"536\" data-end=\"570\">Eaton Pad-Mounted Transformers<\/strong> are factory-assembled, self-contained, and weatherproof distribution transformers designed for safe and reliable power delivery in outdoor and public-facing environments. With power ratings from <strong data-start=\"766\" data-end=\"795\">75 kVA to over 10,000 kVA<\/strong> and primary voltages up to <strong data-start=\"823\" data-end=\"834\">34.5 kV<\/strong>, these units are ideal for <strong data-start=\"862\" data-end=\"970\">urban infrastructure, commercial centers, renewable installations, utility substations, industrial parks<\/strong>, and <strong data-start=\"976\" data-end=\"1019\">campus-style power distribution systems<\/strong>.<\/p>\n<p class=\"\" data-start=\"1022\" data-end=\"1218\">They are available in both <strong data-start=\"1049\" data-end=\"1063\">live-front<\/strong> and <strong data-start=\"1068\" data-end=\"1082\">dead-front<\/strong> configurations and come fully enclosed in tamper-resistant cabinets that are ideal for installations in areas accessible to the public.<\/p>","protected":false},"featured_media":1627,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[163],"product_cat":[175,143],"product_tag":[189,191,146],"class_list":{"0":"post-1626","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-eaton","7":"product_cat-pad-mounted-transformers","8":"product_cat-transformers","9":"product_tag-eaton-transformers","10":"product_tag-pad-mounted-transformers","11":"product_tag-transformers","13":"first","14":"instock","15":"shipping-taxable","16":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/shopstemaengineering.com\/fr\/wp-json\/wp\/v2\/product\/1626","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/shopstemaengineering.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/shopstemaengineering.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/shopstemaengineering.com\/fr\/wp-json\/wp\/v2\/comments?post=1626"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/shopstemaengineering.com\/fr\/wp-json\/wp\/v2\/media\/1627"}],"wp:attachment":[{"href":"https:\/\/shopstemaengineering.com\/fr\/wp-json\/wp\/v2\/media?parent=1626"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/shopstemaengineering.com\/fr\/wp-json\/wp\/v2\/product_brand?post=1626"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/shopstemaengineering.com\/fr\/wp-json\/wp\/v2\/product_cat?post=1626"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/shopstemaengineering.com\/fr\/wp-json\/wp\/v2\/product_tag?post=1626"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}