{"id":1617,"date":"2025-05-07T22:18:05","date_gmt":"2025-05-07T22:18:05","guid":{"rendered":"https:\/\/shopstemaengineering.com\/?post_type=product&#038;p=1617"},"modified":"2026-04-18T14:13:57","modified_gmt":"2026-04-18T14:13:57","slug":"eaton-medium-voltage-transformers-2-4-34-5-kv-up-to-10000-kva","status":"publish","type":"product","link":"https:\/\/shopstemaengineering.com\/fr\/produit\/eaton-medium-voltage-transformers-2-4-34-5-kv-up-to-10000-kva\/","title":{"rendered":"Eaton Medium-Voltage Transformers (2.4 \u2013 34.5 kV | Up to 10,000+ kVA)"},"content":{"rendered":"<h3 class=\"\" data-start=\"346\" data-end=\"459\">Reliable Distribution for Industrial, Utility &amp; Critical Infrastructure (2.4 \u2013 34.5 kV | Up to 10,000+ kVA)<\/h3>\n<p class=\"\" data-start=\"460\" data-end=\"568\">\ud83d\udcde <strong data-start=\"463\" data-end=\"481\">Call\/WhatsApp:<\/strong> +254 707 122 122 | \ud83c\udf10 <strong data-start=\"504\" data-end=\"568\"><a class=\"\" href=\"https:\/\/shopstemaengineering.com\/fr\/\" target=\"_new\" rel=\"noopener\" data-start=\"506\" data-end=\"566\">shopstemaengineering.com<\/a><\/strong><\/p>\n<hr class=\"\" data-start=\"570\" data-end=\"573\" \/>\n<hr class=\"\" data-start=\"1253\" data-end=\"1256\" \/>\n<h2 class=\"\" data-start=\"1258\" data-end=\"1288\">\u2699\ufe0f Technical Specifications<\/h2>\n<div class=\"_tableContainer_16hzy_1\">\n<div class=\"_tableWrapper_16hzy_14 group flex w-fit flex-col-reverse\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"1290\" data-end=\"2455\">\n<thead data-start=\"1290\" data-end=\"1379\">\n<tr data-start=\"1290\" data-end=\"1379\">\n<th data-start=\"1290\" data-end=\"1322\" data-col-size=\"sm\"><strong data-start=\"1292\" data-end=\"1303\">Feature<\/strong><\/th>\n<th data-start=\"1322\" data-end=\"1379\" data-col-size=\"sm\"><strong data-start=\"1324\" data-end=\"1352\">Specifications \/ Options<\/strong><\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"1470\" data-end=\"2455\">\n<tr data-start=\"1470\" data-end=\"1559\">\n<td data-start=\"1470\" data-end=\"1501\" data-col-size=\"sm\"><strong data-start=\"1472\" data-end=\"1489\">Voltage Range<\/strong><\/td>\n<td data-col-size=\"sm\" data-start=\"1501\" data-end=\"1559\">2.4 kV \u2013 34.5 kV (Primary)<\/td>\n<\/tr>\n<tr data-start=\"1560\" data-end=\"1649\">\n<td data-start=\"1560\" data-end=\"1591\" data-col-size=\"sm\"><strong data-start=\"1562\" data-end=\"1583\">Secondary Voltage<\/strong><\/td>\n<td data-col-size=\"sm\" data-start=\"1591\" data-end=\"1649\">480 V \u2013 15 kV (typical)<\/td>\n<\/tr>\n<tr data-start=\"1650\" data-end=\"1739\">\n<td data-start=\"1650\" data-end=\"1681\" data-col-size=\"sm\"><strong data-start=\"1652\" data-end=\"1668\">Power Rating<\/strong><\/td>\n<td data-col-size=\"sm\" data-start=\"1681\" data-end=\"1739\">300 kVA \u2013 10,000+ kVA<\/td>\n<\/tr>\n<tr data-start=\"1740\" data-end=\"1829\">\n<td data-start=\"1740\" data-end=\"1771\" data-col-size=\"sm\"><strong data-start=\"1742\" data-end=\"1751\">Phase<\/strong><\/td>\n<td data-col-size=\"sm\" data-start=\"1771\" data-end=\"1829\">Three-phase<\/td>\n<\/tr>\n<tr data-start=\"1830\" data-end=\"1918\">\n<td data-start=\"1830\" data-end=\"1861\" data-col-size=\"sm\"><strong data-start=\"1832\" data-end=\"1848\">Cooling Type<\/strong><\/td>\n<td data-col-size=\"sm\" data-start=\"1861\" data-end=\"1918\">ONAN \/ ONAF (Oil), Air-cooled (Dry-type)<\/td>\n<\/tr>\n<tr data-start=\"1919\" data-end=\"2007\">\n<td data-start=\"1919\" data-end=\"1950\" data-col-size=\"sm\"><strong data-start=\"1921\" data-end=\"1935\">Insulation<\/strong><\/td>\n<td data-col-size=\"sm\" data-start=\"1950\" data-end=\"2007\">Class OA \/ AA \/ FA \/ AF<\/td>\n<\/tr>\n<tr data-start=\"2008\" data-end=\"2097\">\n<td data-start=\"2008\" data-end=\"2039\" data-col-size=\"sm\"><strong data-start=\"2010\" data-end=\"2018\">Taps<\/strong><\/td>\n<td data-col-size=\"sm\" data-start=\"2039\" data-end=\"2097\">+\/- 2 x 2.5% or +\/- 5% on primary side<\/td>\n<\/tr>\n<tr data-start=\"2098\" data-end=\"2187\">\n<td data-start=\"2098\" data-end=\"2129\" data-col-size=\"sm\"><strong data-start=\"2100\" data-end=\"2113\">Frequency<\/strong><\/td>\n<td data-col-size=\"sm\" data-start=\"2129\" data-end=\"2187\">50 Hz \/ 60 Hz<\/td>\n<\/tr>\n<tr data-start=\"2188\" data-end=\"2276\">\n<td data-start=\"2188\" data-end=\"2219\" data-col-size=\"sm\"><strong data-start=\"2190\" data-end=\"2202\">Mounting<\/strong><\/td>\n<td data-start=\"2219\" data-end=\"2276\" data-col-size=\"sm\">Pad-mounted \/ Substation \/ Pole-mounted<\/td>\n<\/tr>\n<tr data-start=\"2277\" data-end=\"2366\">\n<td data-start=\"2277\" data-end=\"2308\" data-col-size=\"sm\"><strong data-start=\"2279\" data-end=\"2293\">Enclosures<\/strong><\/td>\n<td data-col-size=\"sm\" data-start=\"2308\" data-end=\"2366\">NEMA 1 \/ 3R \/ 4 \/ custom<\/td>\n<\/tr>\n<tr data-start=\"2367\" data-end=\"2455\">\n<td data-start=\"2367\" data-end=\"2398\" data-col-size=\"sm\"><strong data-start=\"2369\" data-end=\"2393\">Standards Compliance<\/strong><\/td>\n<td data-start=\"2398\" data-end=\"2455\" data-col-size=\"sm\">IEEE, ANSI C57, IEC, DOE, CSA, UL<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"sticky end-(--thread-content-margin) h-0 self-end select-none\">\n<div class=\"absolute end-0 flex items-end\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<hr class=\"\" data-start=\"2457\" data-end=\"2460\" \/>\n<h2 class=\"\" data-start=\"2462\" data-end=\"2491\">\ud83c\udfc6 Key Features &amp; Benefits<\/h2>\n<h3 class=\"\" data-start=\"2493\" data-end=\"2527\">\u2705 Versatility in Application<\/h3>\n<ul data-start=\"2528\" data-end=\"2634\">\n<li class=\"\" data-start=\"2528\" data-end=\"2634\">\n<p class=\"\" data-start=\"2530\" data-end=\"2634\">Suitable for <strong data-start=\"2543\" data-end=\"2566\">utility substations<\/strong>, <strong data-start=\"2568\" data-end=\"2582\">renewables<\/strong>, <strong data-start=\"2584\" data-end=\"2608\">commercial complexes<\/strong>, and <strong data-start=\"2614\" data-end=\"2634\">industrial loads<\/strong><\/p>\n<\/li>\n<\/ul>\n<h3 class=\"\" data-start=\"2636\" data-end=\"2671\">\ud83d\udca1 Energy-Efficient Operation<\/h3>\n<ul data-start=\"2672\" data-end=\"2813\">\n<li class=\"\" data-start=\"2672\" data-end=\"2738\">\n<p class=\"\" data-start=\"2674\" data-end=\"2738\">Optimized core and coil designs reduce no-load and load losses<\/p>\n<\/li>\n<li class=\"\" data-start=\"2739\" data-end=\"2813\">\n<p class=\"\" data-start=\"2741\" data-end=\"2813\">Exceeds many international efficiency standards (DOE, C57.12, IEC 60076)<\/p>\n<\/li>\n<\/ul>\n<h3 class=\"\" data-start=\"2815\" data-end=\"2843\">\ud83d\udd12 Safety &amp; Durability<\/h3>\n<ul data-start=\"2844\" data-end=\"3017\">\n<li class=\"\" data-start=\"2844\" data-end=\"2945\">\n<p class=\"\" data-start=\"2846\" data-end=\"2945\">Built-in temperature sensors, pressure relief devices, and pressure vacuum gauges (for oil units)<\/p>\n<\/li>\n<li class=\"\" data-start=\"2946\" data-end=\"3017\">\n<p class=\"\" data-start=\"2948\" data-end=\"3017\">Optional arc-flash mitigation, surge arresters, and protective relays<\/p>\n<\/li>\n<\/ul>\n<h3 class=\"\" data-start=\"3019\" data-end=\"3044\">\ud83e\udde9 Flexible Designs<\/h3>\n<ul data-start=\"3045\" data-end=\"3201\">\n<li class=\"\" data-start=\"3045\" data-end=\"3117\">\n<p class=\"\" data-start=\"3047\" data-end=\"3117\">Available in <strong data-start=\"3060\" data-end=\"3077\">liquid-filled<\/strong>, <strong data-start=\"3079\" data-end=\"3091\">dry-type<\/strong>, and <strong data-start=\"3097\" data-end=\"3115\">sealed designs<\/strong><\/p>\n<\/li>\n<li class=\"\" data-start=\"3118\" data-end=\"3201\">\n<p class=\"\" data-start=\"3120\" data-end=\"3201\">Custom-configured windings, bushings, cooling options, and protection accessories<\/p>\n<\/li>\n<\/ul>\n<h3 class=\"\" data-start=\"3203\" data-end=\"3236\">\ud83c\udf0d Environmentally Friendly<\/h3>\n<ul data-start=\"3237\" data-end=\"3398\">\n<li class=\"\" data-start=\"3237\" data-end=\"3331\">\n<p class=\"\" data-start=\"3239\" data-end=\"3331\">Use of <strong data-start=\"3246\" data-end=\"3278\">natural esters (Envirotemp\u2122)<\/strong> or <strong data-start=\"3282\" data-end=\"3298\">sealed tanks<\/strong> to minimize environmental risk<\/p>\n<\/li>\n<li class=\"\" data-start=\"3332\" data-end=\"3398\">\n<p class=\"\" data-start=\"3334\" data-end=\"3398\">Dry-type options available for indoor use or eco-sensitive zones<\/p>\n<\/li>\n<\/ul>\n<hr class=\"\" data-start=\"3400\" data-end=\"3403\" \/>\n<h2 class=\"\" data-start=\"3405\" data-end=\"3441\">\ud83e\uddea Types of Eaton MV Transformers<\/h2>\n<div class=\"_tableContainer_16hzy_1\">\n<div class=\"_tableWrapper_16hzy_14 group flex w-fit flex-col-reverse\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"3443\" data-end=\"4055\">\n<thead data-start=\"3443\" data-end=\"3544\">\n<tr data-start=\"3443\" data-end=\"3544\">\n<th data-start=\"3443\" data-end=\"3478\" data-col-size=\"sm\"><strong data-start=\"3445\" data-end=\"3453\">Type<\/strong><\/th>\n<th data-start=\"3478\" data-end=\"3523\" data-col-size=\"md\"><strong data-start=\"3480\" data-end=\"3495\">Typical Use<\/strong><\/th>\n<th data-start=\"3523\" data-end=\"3544\" data-col-size=\"sm\"><strong data-start=\"3525\" data-end=\"3535\">Design<\/strong><\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"3648\" data-end=\"4055\">\n<tr data-start=\"3648\" data-end=\"3749\">\n<td data-start=\"3648\" data-end=\"3682\" data-col-size=\"sm\"><strong data-start=\"3650\" data-end=\"3679\">Liquid-Filled Pad-Mounted<\/strong><\/td>\n<td data-col-size=\"md\" data-start=\"3682\" data-end=\"3728\">Outdoor distribution in commercial\/utility<\/td>\n<td data-col-size=\"sm\" data-start=\"3728\" data-end=\"3749\">Sealed or vented<\/td>\n<\/tr>\n<tr data-start=\"3750\" data-end=\"3851\">\n<td data-start=\"3750\" data-end=\"3784\" data-col-size=\"sm\"><strong data-start=\"3752\" data-end=\"3775\">Dry-Type Cast Resin<\/strong><\/td>\n<td data-col-size=\"md\" data-start=\"3784\" data-end=\"3830\">Indoor use \u2013 industrial, tunnels, buildings<\/td>\n<td data-col-size=\"sm\" data-start=\"3830\" data-end=\"3851\">Self-cooled<\/td>\n<\/tr>\n<tr data-start=\"3852\" data-end=\"3953\">\n<td data-start=\"3852\" data-end=\"3886\" data-col-size=\"sm\"><strong data-start=\"3854\" data-end=\"3881\">Substation Transformers<\/strong><\/td>\n<td data-col-size=\"md\" data-start=\"3886\" data-end=\"3932\">High-demand infrastructure, data centers<\/td>\n<td data-col-size=\"sm\" data-start=\"3932\" data-end=\"3953\">Oil-cooled or dry<\/td>\n<\/tr>\n<tr data-start=\"3954\" data-end=\"4055\">\n<td data-start=\"3954\" data-end=\"3988\" data-col-size=\"sm\"><strong data-start=\"3956\" data-end=\"3985\">Pole-Mounted Transformers<\/strong><\/td>\n<td data-col-size=\"md\" data-start=\"3988\" data-end=\"4034\">Rural or small-grid power delivery<\/td>\n<td data-col-size=\"sm\" data-start=\"4034\" data-end=\"4055\">Oil-filled<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"sticky end-(--thread-content-margin) h-0 self-end select-none\">\n<div class=\"absolute end-0 flex items-end\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<hr class=\"\" data-start=\"4057\" data-end=\"4060\" \/>\n<h2 class=\"\" data-start=\"4062\" data-end=\"4103\">\ud83c\udd9a Eaton vs Competitor MV Transformers<\/h2>\n<div class=\"_tableContainer_16hzy_1\">\n<div class=\"_tableWrapper_16hzy_14 group flex w-fit flex-col-reverse\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"4105\" data-end=\"4796\">\n<thead data-start=\"4105\" data-end=\"4202\">\n<tr data-start=\"4105\" data-end=\"4202\">\n<th data-start=\"4105\" data-end=\"4133\" data-col-size=\"sm\"><strong data-start=\"4107\" data-end=\"4118\">Feature<\/strong><\/th>\n<th data-start=\"4133\" data-end=\"4169\" data-col-size=\"sm\"><strong data-start=\"4135\" data-end=\"4160\">Eaton MV Transformers<\/strong><\/th>\n<th data-start=\"4169\" data-end=\"4202\" data-col-size=\"sm\"><strong data-start=\"4171\" data-end=\"4195\">Generic Alternatives<\/strong><\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"4301\" data-end=\"4796\">\n<tr data-start=\"4301\" data-end=\"4399\">\n<td data-start=\"4301\" data-end=\"4329\" data-col-size=\"sm\">Efficiency Standards<\/td>\n<td data-col-size=\"sm\" data-start=\"4329\" data-end=\"4365\">\u2705 DOE \/ C57 \/ IEC Compliant<\/td>\n<td data-col-size=\"sm\" data-start=\"4365\" data-end=\"4399\">\u26a0\ufe0f Varies by manufacturer<\/td>\n<\/tr>\n<tr data-start=\"4400\" data-end=\"4498\">\n<td data-start=\"4400\" data-end=\"4428\" data-col-size=\"sm\">Dry &amp; Liquid Options<\/td>\n<td data-col-size=\"sm\" data-start=\"4428\" data-end=\"4464\">\u2705 Both Available<\/td>\n<td data-col-size=\"sm\" data-start=\"4464\" data-end=\"4498\">\ud83d\udd38 Some offer only liquid<\/td>\n<\/tr>\n<tr data-start=\"4499\" data-end=\"4597\">\n<td data-start=\"4499\" data-end=\"4527\" data-col-size=\"sm\">Eco-Friendly Insulation<\/td>\n<td data-col-size=\"sm\" data-start=\"4527\" data-end=\"4563\">\u2705 Natural ester (Envirotemp\u2122)<\/td>\n<td data-col-size=\"sm\" data-start=\"4563\" data-end=\"4597\">\ud83d\udd38 Mineral oil only<\/td>\n<\/tr>\n<tr data-start=\"4598\" data-end=\"4697\">\n<td data-start=\"4598\" data-end=\"4626\" data-col-size=\"sm\">Factory Testing<\/td>\n<td data-col-size=\"sm\" data-start=\"4626\" data-end=\"4662\">\u2705 100% routine &amp; type tested<\/td>\n<td data-col-size=\"sm\" data-start=\"4662\" data-end=\"4697\">\u26a0\ufe0f Type testing not always done<\/td>\n<\/tr>\n<tr data-start=\"4698\" data-end=\"4796\">\n<td data-start=\"4698\" data-end=\"4726\" data-col-size=\"sm\">Customization<\/td>\n<td data-col-size=\"sm\" data-start=\"4726\" data-end=\"4762\">\u2705 High (Taps, voltage, enclosures)<\/td>\n<td data-col-size=\"sm\" data-start=\"4762\" data-end=\"4796\">\ud83d\udd38 Limited standard models<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"sticky end-(--thread-content-margin) h-0 self-end select-none\">\n<div class=\"absolute end-0 flex items-end\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<hr class=\"\" data-start=\"4798\" data-end=\"4801\" \/>\n<h2 class=\"\" data-start=\"4803\" data-end=\"4827\">\ud83c\udfd7\ufe0f Use Case Examples<\/h2>\n<div class=\"_tableContainer_16hzy_1\">\n<div class=\"_tableWrapper_16hzy_14 group flex w-fit flex-col-reverse\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"4829\" data-end=\"5447\">\n<thead data-start=\"4829\" data-end=\"4915\">\n<tr data-start=\"4829\" data-end=\"4915\">\n<th data-start=\"4829\" data-end=\"4856\" data-col-size=\"sm\"><strong data-start=\"4831\" data-end=\"4843\">Industry<\/strong><\/th>\n<th data-start=\"4856\" data-end=\"4915\" data-col-size=\"md\"><strong data-start=\"4858\" data-end=\"4873\">Application<\/strong><\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"5004\" data-end=\"5447\">\n<tr data-start=\"5004\" data-end=\"5091\">\n<td data-start=\"5004\" data-end=\"5031\" data-col-size=\"sm\"><strong data-start=\"5006\" data-end=\"5019\">Utilities<\/strong><\/td>\n<td data-col-size=\"md\" data-start=\"5031\" data-end=\"5091\">Grid distribution, renewable energy step-down<\/td>\n<\/tr>\n<tr data-start=\"5092\" data-end=\"5180\">\n<td data-start=\"5092\" data-end=\"5119\" data-col-size=\"sm\"><strong data-start=\"5094\" data-end=\"5111\">Manufacturing<\/strong><\/td>\n<td data-col-size=\"md\" data-start=\"5119\" data-end=\"5180\">Powering medium-voltage motors, plant distribution<\/td>\n<\/tr>\n<tr data-start=\"5181\" data-end=\"5269\">\n<td data-start=\"5181\" data-end=\"5208\" data-col-size=\"sm\"><strong data-start=\"5183\" data-end=\"5199\">Data Centers<\/strong><\/td>\n<td data-col-size=\"md\" data-start=\"5208\" data-end=\"5269\">Medium-voltage UPS interfacing, critical load balancing<\/td>\n<\/tr>\n<tr data-start=\"5270\" data-end=\"5358\">\n<td data-start=\"5270\" data-end=\"5297\" data-col-size=\"sm\"><strong data-start=\"5272\" data-end=\"5294\">Mining &amp; Oil &amp; Gas<\/strong><\/td>\n<td data-col-size=\"md\" data-start=\"5297\" data-end=\"5358\">Process equipment, pumping stations, conveyor systems<\/td>\n<\/tr>\n<tr data-start=\"5359\" data-end=\"5447\">\n<td data-start=\"5359\" data-end=\"5386\" data-col-size=\"sm\"><strong data-start=\"5361\" data-end=\"5385\">Airports &amp; Hospitals<\/strong><\/td>\n<td data-col-size=\"md\" data-start=\"5386\" data-end=\"5447\">Substations, uninterrupted facility-wide distribution<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"sticky end-(--thread-content-margin) h-0 self-end select-none\">\n<div class=\"absolute end-0 flex items-end\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<hr class=\"\" data-start=\"5449\" data-end=\"5452\" \/>\n<h2 class=\"\" data-start=\"5454\" data-end=\"5494\">\ud83e\uddfe Sample Eaton MV Transformer Models<\/h2>\n<div class=\"_tableContainer_16hzy_1\">\n<div class=\"_tableWrapper_16hzy_14 group flex w-fit flex-col-reverse\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"5496\" data-end=\"6175\">\n<thead data-start=\"5496\" data-end=\"5606\">\n<tr data-start=\"5496\" data-end=\"5606\">\n<th data-start=\"5496\" data-end=\"5521\" data-col-size=\"sm\"><strong data-start=\"5498\" data-end=\"5507\">Model<\/strong><\/th>\n<th data-start=\"5521\" data-end=\"5538\" data-col-size=\"sm\"><strong data-start=\"5523\" data-end=\"5537\">kVA Rating<\/strong><\/th>\n<th data-start=\"5538\" data-end=\"5566\" data-col-size=\"sm\"><strong data-start=\"5540\" data-end=\"5563\">Primary \/ Secondary<\/strong><\/th>\n<th data-start=\"5566\" data-end=\"5580\" data-col-size=\"sm\"><strong data-start=\"5568\" data-end=\"5579\">Cooling<\/strong><\/th>\n<th data-start=\"5580\" data-end=\"5606\" data-col-size=\"sm\"><strong data-start=\"5582\" data-end=\"5597\">Application<\/strong><\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"5720\" data-end=\"6175\">\n<tr data-start=\"5720\" data-end=\"5833\">\n<td data-start=\"5720\" data-end=\"5746\" data-col-size=\"sm\">VPI-MV-1500-15\/0.48<\/td>\n<td data-col-size=\"sm\" data-start=\"5746\" data-end=\"5763\">1500 kVA<\/td>\n<td data-col-size=\"sm\" data-start=\"5763\" data-end=\"5792\">15 kV \/ 480 V<\/td>\n<td data-col-size=\"sm\" data-start=\"5792\" data-end=\"5806\">Dry-type<\/td>\n<td data-col-size=\"sm\" data-start=\"5806\" data-end=\"5833\">Industrial substation<\/td>\n<\/tr>\n<tr data-start=\"5834\" data-end=\"5947\">\n<td data-start=\"5834\" data-end=\"5860\" data-col-size=\"sm\">PPMT-2500-34.5\/13.8<\/td>\n<td data-col-size=\"sm\" data-start=\"5860\" data-end=\"5877\">2500 kVA<\/td>\n<td data-col-size=\"sm\" data-start=\"5877\" data-end=\"5906\">34.5 kV \/ 13.8 kV<\/td>\n<td data-col-size=\"sm\" data-start=\"5906\" data-end=\"5920\">Oil-cooled<\/td>\n<td data-col-size=\"sm\" data-start=\"5920\" data-end=\"5947\">Utility pad-mounted<\/td>\n<\/tr>\n<tr data-start=\"5948\" data-end=\"6061\">\n<td data-start=\"5948\" data-end=\"5974\" data-col-size=\"sm\">CRDT-3000-24.9\/0.48<\/td>\n<td data-col-size=\"sm\" data-start=\"5974\" data-end=\"5991\">3000 kVA<\/td>\n<td data-col-size=\"sm\" data-start=\"5991\" data-end=\"6020\">24.9 kV \/ 480 V<\/td>\n<td data-col-size=\"sm\" data-start=\"6020\" data-end=\"6034\">Dry-type<\/td>\n<td data-col-size=\"sm\" data-start=\"6034\" data-end=\"6061\">Data center UPS system<\/td>\n<\/tr>\n<tr data-start=\"6062\" data-end=\"6175\">\n<td data-start=\"6062\" data-end=\"6088\" data-col-size=\"sm\">LFT-5000-33\/6.6<\/td>\n<td data-col-size=\"sm\" data-start=\"6088\" data-end=\"6105\">5000 kVA<\/td>\n<td data-col-size=\"sm\" data-start=\"6105\" data-end=\"6134\">33 kV \/ 6.6 kV<\/td>\n<td data-col-size=\"sm\" data-start=\"6134\" data-end=\"6148\">Oil-cooled<\/td>\n<td data-col-size=\"sm\" data-start=\"6148\" data-end=\"6175\">Mining operation<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"sticky end-(--thread-content-margin) h-0 self-end select-none\">\n<div class=\"absolute end-0 flex items-end\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<hr class=\"\" data-start=\"6177\" data-end=\"6180\" \/>\n<h2 class=\"\" data-start=\"6182\" data-end=\"6246\">\ud83d\udd27 Why Buy Eaton MV Transformers from Shop Stema Engineering?<\/h2>\n<ul data-start=\"6248\" data-end=\"6565\">\n<li class=\"\" data-start=\"6248\" data-end=\"6306\">\n<p class=\"\" data-start=\"6250\" data-end=\"6306\">\ud83d\udd0d <strong data-start=\"6253\" data-end=\"6304\">Project-specific sizing &amp; specification support<\/strong><\/p>\n<\/li>\n<li class=\"\" data-start=\"6307\" data-end=\"6373\">\n<p class=\"\" data-start=\"6309\" data-end=\"6373\">\u2699\ufe0f <strong data-start=\"6312\" data-end=\"6371\">Factory-certified installation, testing &amp; commissioning<\/strong><\/p>\n<\/li>\n<li class=\"\" data-start=\"6374\" data-end=\"6433\">\n<p class=\"\" data-start=\"6376\" data-end=\"6433\">\ud83d\udce6 <strong data-start=\"6379\" data-end=\"6431\">Quick lead times on standard &amp; customized builds<\/strong><\/p>\n<\/li>\n<li class=\"\" data-start=\"6434\" data-end=\"6504\">\n<p class=\"\" data-start=\"6436\" data-end=\"6504\">\ud83e\uddfe <strong data-start=\"6439\" data-end=\"6502\">Compliance documentation, drawings, and warranties provided<\/strong><\/p>\n<\/li>\n<li class=\"\" data-start=\"6505\" data-end=\"6565\">\n<p class=\"\" data-start=\"6507\" data-end=\"6565\">\ud83c\uddf0\ud83c\uddea <strong data-start=\"6512\" data-end=\"6563\">Local Kenyan support team with expert knowledge<\/strong><\/p>\n<\/li>\n<\/ul>\n<hr class=\"\" data-start=\"6567\" data-end=\"6570\" \/>\n<h2 class=\"\" data-start=\"6572\" data-end=\"6614\">\ud83d\udcde Request a Quote or Site Survey Today<\/h2>\n<p class=\"\" data-start=\"6616\" data-end=\"6790\">Power your mission-critical infrastructure with <strong data-start=\"6664\" data-end=\"6707\">Eaton\u2019s proven medium-voltage solutions<\/strong>, backed by Shop Stema Engineering\u2019s technical expertise and commitment to service.<\/p>\n<p class=\"\" data-start=\"6792\" data-end=\"6965\">\ud83d\udcde <strong data-start=\"6795\" data-end=\"6813\">Call\/WhatsApp:<\/strong> +254 707 122 122<br data-start=\"6830\" data-end=\"6833\" \/>\ud83d\udce7 <strong data-start=\"6836\" data-end=\"6846\">Email:<\/strong> <a class=\"cursor-pointer\" rel=\"noopener\" data-start=\"6847\" data-end=\"6872\">info@stemaengineering.com<\/a><\/p>","protected":false},"excerpt":{"rendered":"<h2 class=\"\" data-start=\"575\" data-end=\"597\">\ud83e\udded Product Overview<\/h2>\n<p class=\"\" data-start=\"599\" data-end=\"1005\"><strong data-start=\"599\" data-end=\"636\">Eaton Medium-Voltage Transformers<\/strong> are engineered to deliver <strong data-start=\"663\" data-end=\"717\">safe, efficient, and continuous power distribution<\/strong> across <strong data-start=\"725\" data-end=\"754\">2.4 kV to 34.5 kV systems<\/strong>, with capacities reaching <strong data-start=\"781\" data-end=\"796\">10,000+ kVA<\/strong>. These transformers are critical in <strong data-start=\"833\" data-end=\"943\">large-scale industrial operations, utility grids, mining, oil &amp; gas, commercial campuses, and data centers<\/strong>, where uptime, durability, and efficiency are non-negotiable.<\/p>\n<p class=\"\" data-start=\"1007\" data-end=\"1251\">Available in <strong data-start=\"1020\" data-end=\"1058\">dry-type and liquid-filled designs<\/strong>, Eaton MV transformers offer robust insulation systems, advanced thermal performance, and customizable configurations for <strong data-start=\"1181\" data-end=\"1215\">primary and secondary voltages<\/strong>, tap settings, and enclosure types.<\/p>","protected":false},"featured_media":1618,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[163],"product_cat":[174,143],"product_tag":[189,179,146],"class_list":{"0":"post-1617","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-eaton","7":"product_cat-medium-voltage-transformers","8":"product_cat-transformers","9":"product_tag-eaton-transformers","10":"product_tag-medium-voltage-transformers","11":"product_tag-transformers","13":"first","14":"instock","15":"shipping-taxable","16":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/shopstemaengineering.com\/fr\/wp-json\/wp\/v2\/product\/1617","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/shopstemaengineering.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/shopstemaengineering.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/shopstemaengineering.com\/fr\/wp-json\/wp\/v2\/comments?post=1617"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/shopstemaengineering.com\/fr\/wp-json\/wp\/v2\/media\/1618"}],"wp:attachment":[{"href":"https:\/\/shopstemaengineering.com\/fr\/wp-json\/wp\/v2\/media?parent=1617"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/shopstemaengineering.com\/fr\/wp-json\/wp\/v2\/product_brand?post=1617"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/shopstemaengineering.com\/fr\/wp-json\/wp\/v2\/product_cat?post=1617"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/shopstemaengineering.com\/fr\/wp-json\/wp\/v2\/product_tag?post=1617"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}